-40%

Metron MP600 4160V Electric Fire Pump Controller 350 HP 1502-V4DBDA 1503F-E4GCD

$ 3432

Availability: 100 in stock

Description

New Surplus Metron MP600 4160V Electric Fire Pump Controller 350Hp
Metron PN: MP600-H-350-4160 included are Allen Bradley PNs: 1503F-E4GCD and 1502-V4DBDA-1
Late model, medium voltage fire pump motor starter/controller from a project that was never completed.  This controller is as factory delivered it.  This fire pump controller contains an Allen Bradley Cat# 1503F-E4GCD electric motor starter assembly with an Allen Bradley vacuum contactor Cat# 1502-V4DBDA-1.  You can pull the Allen Bradley starter and use it in any application as needed or use the complete unit as intended!  New, never energized and ready to go to work!!
Brand: Metron
Model: MP600H-350-4160
Serial # 23425511
Electrical Rating: 350Hp
Amps: 47
Volts: 4160
Phase: 3
Class: E2
BIL Rating: 60kV
Control Input Voltage: 120VAC
Maximum Operating Pressure: 300PSI
UL Listed, FM Approved, Mfg in Year 2012
Inside Metron Enclosure is Allen Bradley Motor Starter Cat# 1503F-E4GCD and
Allen Bradley Vacuum Contactor Cat # 1502-V4DBDA-a
SER: E, Voltage 2500-7200
Phase: 3
Amps: 400
Hertz: 50/60
Interrupting Capacity: 6000Amp
Altitude Range: 0-1000 Meters
Description from Metron's website:
"The Metron Series MP600 High Voltage Fire Pump Controllers are a modular concept system, which utilize "state-of-the-art" vacuum bottle technology.  The primary control element in the MP600 is a fixed mount style vacuum bottle contactor with isolating disconnect switch.  Integral to the disconnect switch are "R" rated current limiting cartridge style fuses.  Space is provided for storage of three spare fuses on the rear of the outer door.  Two fused potential/control transformers (PTs) are also contained within the cabinet.  These transformers provide both input signals to the monitor circuits as well as control power for the MP600.  For testing purposes, it is possible to supply 120VAC power directly to the control section through a built-in test receptacle and test switch.  The MP600 has both front and rear access.  Front access is for easy access to the control circuits.  Rear access is provided for termination of the incoming power and termination of the motor connections.  Incoming power and motor connections enter through the bottom of the controller enclosure.  Locked rotor motor protection is provided by the microprocessor control unit per the requirements of NFPA 20, Chapter 10.  The microprocessor control unit also provides contacts for remote alarm of phase reversal, low voltage, single phase, loss of voltage, motor tripped, and motor overload.  The Operator Interface Device (OID) has LED lamps for Power On, Power Failure, System Failure, Motor Overload, and Motor Tripped.  The OID also displays three phase voltage and current along with system water pressure.  The standard MP600 is supplied in a NEMA type 2 enclosure which is fabricated from 12 gauge steel.  Minimum floor clearance of 12 inches (304.8 mm) is provided with allowances for floor anchoring.  The MP600 is protected with two hinged removable, gasketed doors, equipped with a 3-point latch, one door for the control section and one door for the high voltage section.  Access to the vacuum contactor is provided by a lockable and interlocked second door, which requires the contactor to be disengaged from the bus prior to opening the door.  Control Wiring and components are accessible behind their own access door.  Access to control components does not require motor de-energization.  A solid copper ground bus is provided through the incoming high voltage and motor termination compartments."
FOB: Belgium, WI 53004 USA
*All products are advertised outside of eBay.  We reserve the right to sell all products outside of eBay for any reason*
Shipping – Freight:
If you are interested in purchasing a larger item which requires freight, please contact us directly for the best freight price possible.   If you would like us to work with a different carrier, or you would like to arrange freight, please contact us and we will give you the pickup address, dimensions, and weight. Please note that items will not be shipped until the freight charges have been paid.